Dell PowerEdge Server Recovery Services

Specialist data recovery for failed Dell servers with PERC RAID controllers. Recovering from hardware failures, crashed arrays, and corrupted configurations.

Emergency Server Recovery

Dell Server Data Recovery Specialists

At Physical Data Recovery, we specialize in recovering data from failed Dell PowerEdge servers with PERC RAID controllers. Our London lab is equipped to handle all Dell server configurations, from single drive failures to complete RAID array collapses.

Critical Server Failure Warning

If your Dell server shows any of these signs, power it off immediately to prevent further data loss:

  • Flashing amber drive indicators
  • "Foreign configuration" warnings
  • PERC controller failure messages
  • Multiple drive failures in RAID array
  • Unusual clicking or beeping sounds

Dell PowerEdge Models We Recover

We successfully recover data from all Dell PowerEdge server generations and configurations:

PowerEdge R-Series

  • R240, R340, R440, R540
  • R640, R740, R740xd, R740xd2
  • R840, R940, R940xa
  • Older R710, R720, R730

PowerEdge T-Series

  • T140, T340, T440, T640
  • T30, T130, T330, T430
  • T620, T630, T320, T420

PowerEdge MX Series

  • MX740c, MX750c, MX760c
  • Modular chassis systems
  • Flexible configurations

Legacy PowerEdge

  • 9th gen (2950, 2970)
  • 10th gen (R410, R510)
  • 11th gen (R515, R715)
  • 12th gen (R520, R620)

Dell PERC RAID Controller Recovery

We recover data from all Dell PERC (PowerEdge RAID Controller) versions and configurations:

PERC H-Series

  • PERC H330, H730, H730P
  • PERC H740P, H745, H840
  • PERC H200, H700, H800
  • PERC H310, H710, H710P

PERC S-Series

  • PERC S130, S140
  • Software RAID solutions
  • Windows-based configurations

MegaRAID-based

  • PERC 6/i, 6/iR
  • PERC 5/i, 5/e, 5/iR
  • PERC 4/DC, 4/SC, 4e/Di
  • Legacy PERC 3/QC, 3/DC

Configuration Preservation

We can recover your original RAID configuration including:

  • Stripe size and block order
  • Disk order and RAID parameters
  • Virtual disk configurations
  • Hot spare assignments

Common Dell Server Failure Scenarios

Drive Failures

  • Multiple drive failures in array
  • Failed rebuild attempts
  • Drive dropouts during rebuild
  • SAS/SATA interface issues

Controller Failures

  • PERC controller failure
  • Configuration corruption
  • Firmware update failures
  • Battery backup unit (BBU) issues

Human Error

  • Accidental drive removal
  • Incorrect drive replacement
  • Wrong RAID initialization
  • Accidental virtual disk deletion

System Issues

  • Power surges/spikes
  • Backplane failures
  • Chassis management errors
  • iDRAC configuration problems

Our Dell Server Recovery Process

  1. Initial Evaluation

    We assess all drives individually in our cleanroom environment (£54 diagnostic fee per drive)

  2. Drive Imaging

    Create sector-by-sector clones of each drive to prevent further damage

  3. PERC Configuration Analysis

    Recover original RAID parameters and virtual disk structure

  4. Virtual Reconstruction

    Rebuild array virtually using specialized Dell PERC tools

  5. Data Extraction

    Recover files with original directory structures and permissions

  6. Verification & Delivery

    Verify data integrity and return on new storage or secure transfer

Business Critical Recovery

We offer 24/7 emergency Dell server recovery with same-day evaluation for critical business systems. Our priority service minimizes downtime and data loss.

Emergency Dell Server Recovery

Our London lab at SE1 5SY is equipped to handle all Dell PowerEdge recovery cases. For business-critical systems, we offer immediate response:

Emergency Line

020 7237 6805

24/7 for critical cases

Call Now

Business Support

support@physicaldatarecovery.co.uk

Guaranteed 1-hour response

Email Now

Courier Service

Nationwide collection

Secure transport

Arrange Pickup